![]() There should be a label that will give you the model number. User Manual: If you don’t know your panel model, look inside the door of the alarm control box. 968XTP High-Security Magnetic Switch Honeywell Security Surface Mount Magnetic Contact. Change Master Code Old Master Code + 8 + 2 + new Master Code + new. Click to find product details, documentation, ordering info and more. C:UsersACS WebMasterDocumentsBasic System Instructions 01.25.11.doc. Most panels this will be terminal 1 on the far left bottom of panel. Learn all about the Honeywell Security 6160 Alpha Display Keypad. If you can’t find it, then pull one AC wire. These recommendations can be found on page 47 of this manual. It is a beige box plugged into a nearby power outlet. Power Down Panel: Pull one wire from the battery, Then unplug the panel transformer if you know where it is. Larger panels require alpha keypads to change codes and will ask questions to complete after the above process is done. If that doesn’t work, use a 1-digit number. Most panels require a 2-digit user number. Clear the detector of smoke and repeat the sequence to reset.Ĭhange Code: It is recommended that you first contact your security company and make changes under their direction. * If smoke has not cleared, the alarm may resound. There might be a reset button on some panel boxes to reset smoke detectors. However, you may have to enter Code + OFF again to reset the smokes. Smoke Reset: Smoke Detectors mostly reset automatically with these panels when alarm is silenced at the keypad. ![]() The panel will bypass zones that are open.” Many panels also allow you to “”Quick Bypass”” by pressing Code + Bypass + #. The very large Vista 100 and Vista 128 panels use 3-digit zone numbers. The keypad will scroll through all faulted zones.īypass Zone(s): “Code + + Zone number(s). Installation Instructions for that Model for further. The 6160 also has a speaker which will beep to indicate system status, entry/exit delay, or alarm situations.The Honeywell 6160 keypad is compatible with the Honeywell Vista series control panels.Check Faulted Zones: Press key. Note: If enrolling a wireless key in high security mode, see the. Both the screen and the keys are backlit. You can always try the default Installer Code first but it. The 6160 keypad has a 32 character display screen which features English status messages. The default Installer Code for all Honeywell/Ademco alarm panels (hardwired and wireless) is 4112. The Honeywell 6160 is an alphanumeric keypad and provides full functionality for programming and controlling a Honeywell Vista series hard-wired security system. Refer to the control panel's programming guide for the complete list of programming commands and explanations. Set keypad-related data fields: *21 Quick Arm Enable, *23 Forced Bypass, and *84 Auto Stay Arm. Use fields *197, *198, and *199 to turn on a partition number display, exit time interval display, and select fail display mode. Use data fields *190-*196 to enable keypad addresses, assign a partition, and enable sound options. Function keys must be held down for 2 seconds to activate an alarm. These keys may be programmed for panic alarms, stay, away and other special functions. Use data field *57 to program the 4 function keys on the right hand side known as A, B, C and D. Or power up the keypad and within 50 seconds of powering up, press the star (*) key and the pound (#) key at the same time, this method needs to be used if ✱98 was used to exit program mode. If you dont have the initial master code then you will need an engineer call out to. To enter programming, enter the installer code (Honeywell's factory default installer code is 4112) followed by the numbers 800. You then need to enter your new 4 digit code, followed by PROG and RESET. How to Change the Date & Time on a Honeywell Vista Security Alarm System Enter your Master Code, the press Press 6 Press 3 Press when the date and time. Keypads programmed with the same address will provide unpredictable results. Each keypad must be assigned a unique address. ![]() ![]() The main keypad address should be addressed to 16. Once installed, to enable the 6160 keypad, start by setting the address at the keypad. Install a Honeywell 6160 keypad to the control panel's keypad terminals as shown in the installation manual. ![]()
0 Comments
Leave a Reply. |